Industrial Multi-Sensor Monitoring & Analytics

Intell-i-Watch

More sensors. More insight. Less complexity.

Technical & Engineering Resources

Technical & Engineering Resources

Brochures, guides, tech notes and engineering information for the Intell-i-Watch line and sensors. Files open as PDFs.

For engineers

Model comparison chart

ModelChannelsScreenDimensionsVoltageWeightMemoryEthernetPart number
IW-3326 (3 analog, 3 digital)3.5”8” × 8” × 6”115 V, 1-phase, 50/60 Hz12 lbs32 GB SD card, 32 GB+ flashYes, networkableIW332VIO
IW-4448 (4 analog, 4 digital)3.5”8” × 8” × 6”115 V, 1-phase, 50/60 Hz12 lbs32 GB SD card, 32 GB+ flashYes, networkableIW444VIO
IW-64610 (6 analog, 4 digital)3.5”8” × 8” × 6”115 V, 1-phase, 50/60 Hz12 lbs32 GB SD card, 32 GB+ flashYes, networkableIW646VIO
IW-Uniscreen VDM8+ (4+ analog, 4+ digital)Based on your screen10” × 10” × 6”115 V, 1-phase, 50/60 Hz12 lbs32 GB SD card, 32 GB+ flashYes, networkableIW-Uniscreen VDM
IW-88816 (8 analog, 8 digital)5”10” × 10” × 6”115 V, 1-phase, 50/60 Hz14 lbs32 GB SD card, 32 GB+ flashYes, networkableIW888UBIO
IW-10101220 (10 analog, 10 digital)5”10” × 10” × 6”115 V, 1-phase, 50/60 Hz14 lbs32 GB SD card, 32 GB+ flashYes, networkableIW101012UB
IW-10241234 (10 analog, 24 digital)7”16” × 14” × 8”115 V, 1-phase, 50/60 Hz28 lbs32 GB SD card, 32 GB+ flashYes, networkableIW102412UB
IW-18261244 (18 analog, 26 digital)10.4”16” × 14” × 8”115 V, 1-phase, 50/60 Hz28 lbs32 GB SD card, 32 GB+ flashYes, networkableIW182612UB
IWCUnlimited, quantity and type as required10”-15”Sized per project115 V, 1-phase, 50/60 Hz; 230/460 V, 3-phase, 50/60 Hz; or as requiredPer project32 GB SD card, 32 GB+ flashYes, networkableIWC

Figures as published for each model. Contact us to confirm the specifications for your project. Download the chart (PDF)

How the Intell-i-Watch works

Your sensors in. Readings, alarms, records and analysis out.

1Your sensors

Water quality

pHORPConductivityDissolved oxygenTurbidity

Process

FlowLevelPressureTemperature

Equipment & energy

Motor run timeOn/off statusPower consumption

Most standard analog and on/off sensors.

2The Watch

Intell-i-Watch

Monitor. Log. Analyze.

pH 17.8Normal
Flow 118.4 gpmNormal
Level 151.7 inNormal

Logs and analyzes on its own – no network needed

3What you get

See it

  • Live readings
  • Trend graphs
  • Averages, min/max
  • Monthly statistics

Get alerted

  • Alarm setpoints you set
  • Delays for process lag
  • Email and text alerts
  • Alarm outputs

Keep the record

  • Date- and time-stamped logs
  • Alarm log
  • Logging rate set to your process

Share it

  • CSV export for Excel
  • Transfer by USB
  • Password-protected web pages

Some features depend on the model. Network connections are optional and turned on only with your approval.

Standalone operation

The Intell-i-Watch logs and analyzes your data inside the monitor itself. No internet, cloud service, plant or IT network, or remote access is needed for that.

  • Analysis keeps working when the network is down, or where there is none.
  • No IT or cloud integration is needed for analysis.
  • Data is analyzed where it is collected.
  • Suited to remote sites and facilities with restricted network access.

Connected features – email and text alerts, web server pages, file transfer and remote viewing – are optional and turned on only with your approval.

Alarm functions

  • Normal, alert and alarm ranges set for each sensor, and changed any time.
  • Alarms can be delayed to allow for process lag, so short, harmless spikes don't set them off.
  • Each sensor's high and low alarms can be enabled or disabled.
  • Alarm logs and time-stamped alarm actions.
  • Email and text alarm notifications are optional, turned on only with your approval.

Data logging and analysis

  • Choose which sensors to record and how often – every second for fast changing events, every couple of minutes for slow ones.
  • Every reading is stored with its date and time.
  • Statistics on the Watch: percent of time in the normal, alert and alarm ranges, minimum and maximum, rolling averages and monthly statistics.
  • Data is kept for the monitoring window you set (2 weeks, 30 days, etc.), subject to the storage capacity in the unit.
  • Data logs export as CSV files for Excel and can be saved on external storage.
  • 32 GB SD card datalogging.

How the analysis window works

Questions? See the frequently asked questions or contact us.

Intell-i-Watch, A Pan America Environmental Brand. For water treatment equipment literature, see Pan America's literature library.

Tell us what you need to monitor